| Min. Cylinder Volume (in3) | Nom. Cylinder Weight (lb) | OD (in) | L (in) | tmin (in) |
| 650 | 32 | 7 | 22.875 | 0.144 |
| DOT Service Pressure (psi) | Air (ft3) | Oxygen (ft3) | Nitrogen (ft3) | Argon (ft3) | Helium (ft3) | Hydrogen (ft3) |
| 2015 | 53 | 57 | 52.7 | 56.8 | 50.2 | 49.4 |
| 10% Overfill Pressure (psi) | Air (ft3) | Oxygen (ft3) | Nitrogen (ft3) | Argon (ft3) | Helium (ft3) |
| 2216 | 57.9 | 62.7 | 57.9 | 62.4 | 55.2 |
| Min. Cylinder Volume (Liter) | Nom. Cylinder Weight (kg) | OD (mm) | L (mm) | tmin (mm) |
| 10.6 | 14.5 | 177.8 | 581.02 | 3.66 |
| DOT Service Pressure (bar) | Air (m3) | Oxygen (m3) | Nitrogen (m3) | Argon (m3) | Helium (m3) | Hydrogen (m3) |
| 139 | 1.5 | 1.61 | 1.49 | 1.61 | 1.42 | 1.39 |
| 10% Overfill Pressure (bar) | Air (m3) | Oxygen (m3) | Nitrogen (m3) | Argon (m3) | Helium (m3) |
| 153 | 1.64 | 1.78 | 1.64 | 1.77 | 1.56 |
For specification information on a particular cylinder, please use our Cylinder Specification feature to find the information you need for our DOT High Pressure, Acetylene, and ISO High Pressure Norris Cylinders.